This article lists all device vendors and models supported through the Edge connector, along with their connection parameters and any device-specific setup required before claiming.
Click a vendor in the index below to jump to and open its section — each lists the supported models, the parameters you'll be asked for, and the setup steps needed on the device to enable monitoring.
ℹ️Parameter types
- Required — must be provided when adding the device
- Optional — can be left blank; the connector will use defaults
⚠️Before you save device credentials
If credentials are not accepted, Xyte keeps retrying on that model's normal polling interval. Many devices lock the account, or block the connecting address, after a few failed sign-ins, and while a device is locked it will reject even correct credentials.
Check the username, password and port before saving. If a device stops responding to management access after credentials were entered, clear the lockout on the device (or wait out its lockout window) before correcting the credentials in Xyte.
Lockout thresholds and timeouts are set by the manufacturer, not by Xyte — check the vendor's own documentation for the model you are claiming.
📘Unless a model below exposes an SNMP community string parameter, Xyte polls it with the default community public. Set the device's community string to public, or it will only ever report heartbeat data. SNMP polling uses UDP port 161, which must also be open from the Edge host to the device.
Acer· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Barco· 2 models
| Model | Parameters | Setup instructions |
|---|
| ClickShare V1 | — | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |
| ClickShare v2 | PasswordoptUsernameopt | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |
BenQ· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Biamp· 2 models
| Model | Parameters | Setup instructions |
|---|
| Tesira Text Protocol (TTP) | PasswordoptPortoptUsernameopt | This device is monitored over the Tesira Text Protocol (TTP) using SSH (port 22). Ensure SSH is enabled on the device and provide its administrator username and password. TTP over telnet (port 23) is not used. |
| TesiraLUX Series | PasswordoptPortoptUsernameopt | This device is monitored over the Tesira Text Protocol (TTP) using SSH (port 22). Ensure SSH is enabled on the device and provide its administrator username and password. TTP over telnet (port 23) is not used. |
BrightSign· 1 model
| Model | Parameters | Setup instructions |
|---|
| Series 5 | PasswordoptProtocolreqUsernameopt | This device is monitored over its HTTP API. Select the protocol (HTTP or HTTPS) configured on the unit and provide the device credentials. |
Canon· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Casio· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Christie· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Cisco· 6 models
| Model | Parameters | Setup instructions |
|---|
| C9300 | SNMP community stringreq | This device is monitored over SNMP. Enable SNMP in the device settings and set the community string; without it, only heartbeat data is available. |
| CBSx series | SNMP community stringreq | This device is monitored over SNMP. Enable SNMP in the device settings and set the community string; without it, only heartbeat data is available. |
| Room Bar | PasswordreqUsernamereq | This device is monitored over its local xAPI using SSH (port 22). Ensure SSH is enabled on the endpoint (NetworkServices SSH Mode: On — enabled by default) and provide a local administrator username and password. |
| Room Kit (EQ, EQX, Pro) | PasswordoptUsernameopt | This device is monitored over its local xAPI using SSH (port 22). Ensure SSH is enabled on the endpoint (NetworkServices SSH Mode: On — enabled by default) and provide a local administrator username and password. |
| Room Navigator | PasswordreqUsernamereq | This device is monitored over its local xAPI using SSH (port 22). Ensure SSH is enabled on the endpoint (NetworkServices SSH Mode: On — enabled by default) and provide a local administrator username and password. |
| SX20 | — | — |
ClockAudio· 1 model
| Model | Parameters | Setup instructions |
|---|
| CDT100 MK3 | — | This device is monitored over a custom ClockAudio protocol; confirm it is accessible through the default port (49494) on the physical device or update to the correct port number in Xyte after claiming. |
Crestron· 16 models
| Model | Parameters | Setup instructions |
|---|
| 4 Series | PasswordreqUsernamereq | This device is monitored over its REST API. Enable the device's web/REST control interface and provide the administrator username and password; without them, only heartbeat data is available. |
| AirMedia Series | PasswordreqUsernamereq | — |
| CEN-ODT-C-POE | PasswordreqUsernamereq | — |
| Crestron Flex Conferencing Kits | PasswordreqUsernamereq | — |
| Crestron Flex Phones | PasswordreqUsernamereq | — |
| Crestron Flex Soundbars | PasswordreqUsernamereq | — |
| Crestron Mercury | PasswordreqUsernamereq | — |
| DM Matrix Switchers | PasswordreqUsernamereq | — |
| DM-NAX Series | PasswordreqUsernamereq | — |
| DM-NVX Series | PasswordreqUsernamereq | This device is monitored over its REST API. Enable the device's web/REST control interface and provide the administrator username and password; without them, only heartbeat data is available. |
| DM-NVX-DIR Series | PasswordreqUsernamereq | This device is monitored over its REST API. Enable the device's web/REST control interface and provide the administrator username and password; without them, only heartbeat data is available. |
| HD-MD 4KZ AV Switchers (REST) | PasswordreqUsernamereq | — |
| IV-SAM Series | PasswordreqUsernamereq | — |
| TS/TSW 60 Series Touch Panels | PasswordreqUsernamereq | — |
| TSS/TSW 4-Series Touch Panels | PasswordreqUsernamereq | This device is monitored over its REST API. Enable the device's web/REST control interface and provide the administrator username and password; without them, only heartbeat data is available. |
| UC Engine | PasswordreqUsernamereq | — |
CyberPower· 2 models
| Model | Parameters | Setup instructions |
|---|
| PDU41XXX | — | This device is monitored over SNMP. Enable SNMP in the device settings and set the community string to public; without it, only heartbeat data is available. |
| Switched PDI (0U/2U) | — | This device is monitored over SNMP. Enable SNMP in the device settings and set the community string to public; without it, only heartbeat data is available. |
Epiphan· 1 model
| Model | Parameters | Setup instructions |
|---|
| Pearl Series | PasswordoptUsernamereq | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |
Epson· 2 models
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
| WorkForce Pro Series Multifunction Printers | — | This device is monitored over SNMP. Enable SNMP in the device settings and set the community string to public; without it, only heartbeat data is available. |
Extreme Networks· 1 model
| Model | Parameters | Setup instructions |
|---|
| X450-G2 Series Switches | — | — |
Extron· 1 model
| Model | Parameters | Setup instructions |
|---|
| DXP HD 4K PLUS | PasswordoptPortoptSelect Specific DXP Modelreq | — |
Fujifilm· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Genelec· 1 model
| Model | Parameters | Setup instructions |
|---|
| Genelec Celing Speaker | PasswordreqPortoptUsernamereq | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |
GUDE· 1 model
| Model | Parameters | Setup instructions |
|---|
| Gude device | HTTP protocoloptPasswordoptUsernameopt | This device is monitored over its HTTP API. Select the protocol (HTTP or HTTPS) configured on the unit and provide the device credentials. |
Hitachi· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
InFocus· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Kiloview· 2 models
| Model | Parameters | Setup instructions |
|---|
| N5/N6 | PasswordreqUsernamereq | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |
| N50/N60 | PasswordreqUsernamereq | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |
LG· 1 model
| Model | Parameters | Setup instructions |
|---|
| U Series | — | Some devices might need to configure the following to enable rich data: 1. Enable the External Control Protocol over IP on the LG display, you generally need to configure the settings within hidden Installation Menu. 2. Set Power Saving/PM Mode to "Network Ready" or equivalent in the Menu to ensure network control is available while the unit is in standby. |
Logitech· 2 models
| Model | Parameters | Setup instructions |
|---|
| Logitech CollabOS | PasswordreqUsernamereq | Ensure Local Network Access (LNA) is enabled on the device to allow standard monitoring and advanced feature support. |
| Rally Bar Series (All-in-One Video Bars) | PasswordreqUsernamereq | — |
Maxell· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Mitsubishi· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Netgear· 1 model
| Model | Parameters | Setup instructions |
|---|
| M4250 AV Line Series Switches | Telnet PasswordreqTelnet PortreqTelnet User Namereq | This device is monitored over Telnet. Enable Telnet access on the device (default port 23) and provide the administrator username and password; without them, only heartbeat data is available. |
⚠️Lockout behaviour on these switches
After three failed logins a NETGEAR switch blocks further attempts, and the block lasts longer each time — up to an hour. While it is blocking, the switch rejects even the correct password, so a device that is being polled with wrong credentials can stay locked until the attempts stop. Clear the lockout on the switch, or stop the polling, before correcting the credentials in Xyte.
Reference: NETGEAR: I'm using the right password, so why can't I log in to my switch?
Novastar· 1 model
| Model | Parameters | Setup instructions |
|---|
| H series | Project IDreqSecretoptUse encryptionreq | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |
Panasonic· 12 models
| Model | Parameters | Setup instructions |
|---|
| All-in-one dvLED | PasswordoptPortoptUsernameopt | This device requires authentication for status monitoring and control. Enter the administrator credentials configured on the device during setup (managed via the device IP / Web UI or the Network Settings menu). Default port: 1024. |
| AW-HN40 | PasswordoptUsernameopt | — |
| AW-UE Camera Series | PasswordoptUsernameopt | — |
| Display | PasswordoptPortoptUsernameopt | This device requires authentication for status monitoring and control. Enter the administrator credentials configured on the device during setup (managed via the device IP / Web UI or the Network Settings menu). Default port: 1024. |
| Displays (PJ Link Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
| DLP Fixed Lens | PasswordoptPortoptUsernameopt | — |
| DLP Interchangeable Lens | PasswordoptPortoptUsernameopt | — |
| LCD Fixed Lens | — | — |
| MZ Series 10K+ | PasswordoptPortoptUsernameopt | — |
| MZ Series 10K- | PasswordoptPortoptUsernameopt | — |
| Projector | PasswordoptPortoptUsernameopt | This device requires authentication for status monitoring and control. Enter the administrator credentials configured on the device during setup (managed via the device IP / Web UI or the Network Settings menu). Default port: 1024. |
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Poly· 1 model
| Model | Parameters | Setup instructions |
|---|
| Poly Studio Series | PasswordreqUsernamereq | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |
QSYS· 1 model
| Model | Parameters | Setup instructions |
|---|
| Core Series | — | This device is monitored over SNMP. Enable SNMP V2C in the device settings and set the community string to public; without it, only heartbeat data is available. |
Ricoh· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Roku· 4 models
| Model | Parameters | Setup instructions |
|---|
| 55S455 | — | This device is monitored via Roku's External Control Protocol (ECP). Without network access enabled, only heartbeat data is available. For full data access, enable control by mobile apps: Settings → System → Advanced system settings → Control by mobile apps → Network access → Enabled. |
| 65S455 | — | This device is monitored via Roku's External Control Protocol (ECP). Without network access enabled, only heartbeat data is available. For full data access, enable control by mobile apps: Settings → System → Advanced system settings → Control by mobile apps → Network access → Enabled. |
| 75S455 | — | This device is monitored via Roku's External Control Protocol (ECP). Without network access enabled, only heartbeat data is available. For full data access, enable control by mobile apps: Settings → System → Advanced system settings → Control by mobile apps → Network access → Enabled. |
| 85S455 | — | This device is monitored via Roku's External Control Protocol (ECP). Without network access enabled, only heartbeat data is available. For full data access, enable control by mobile apps: Settings → System → Advanced system settings → Control by mobile apps → Network access → Enabled. |
Samsung· 2 models
| Model | Parameters | Setup instructions |
|---|
| QMC Series | Display IDopt | Verify that the MDC control protocol (might be referenced as "PC Connection" in OSD) is RJ45 (LAN) / Wi-Fi Network (and not RS-232). This configuration is located under the "System Settings" sub-menu in some Samsung screens. Make sure communication remains available when the screen is off or in standby mode. To do this, enable "Network Standby". This configuration is located under "System" > "Power Control" in some Samsung screens. |
| WMR Series | Display IDopt | — |
Sennheiser· 1 model
| Model | Parameters | Setup instructions |
|---|
| TeamConnect Bar Series | PasswordoptUsernameopt | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |
Sharp / NEC· 1 model
| Model | Parameters | Setup instructions |
|---|
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Shure· 6 models
| Model | Parameters | Setup instructions |
|---|
| IntelliMix P300 Conferencing DSP | — | This device is monitored over Shure's network control protocol. Enable network/command control and ensure the device firmware is up to date; older firmware does not support network control. |
| Microflex Advance Series Array Microphones | — | This device is monitored over its HTTPS REST API (port 443). No credentials are required — ensure the device is reachable on port 443 and that its firmware supports the device-management REST API. |
| MXA310 | — | This device is monitored over Shure's network control protocol. Enable network/command control and ensure the device firmware is up to date; older firmware does not support network control. |
| MXA910 | — | This device is monitored over Shure's network control protocol. Enable network/command control and ensure the device firmware is up to date; older firmware does not support network control. |
| SBC850 | — | — |
| ULXD4 | — | This device is monitored over Shure's network control protocol. Enable network/command control and ensure the device firmware is up to date; older firmware does not support network control. |
Sony· 2 models
| Model | Parameters | Setup instructions |
|---|
| Pro BRAVIA | Authentication Codereq | This device is monitored via Sony IP Control and returns basic status data automatically (no action required). For full data access, enable Network/IP Control (Simple IP) on the display and supply the pre-shared key (PSK). |
| Projectors (PJLink Enabled) | PasswordoptPortopt | This device is monitored over PJLink. Enable PJLink on the device and provide port if non default PJLink port (4352) is configured. Provide the PJLink password if one is configured. The Edge must be able to reach the device on the PJLink port (4352 by default) — if it is blocked on the network, the device shows as reachable but never reports data. |
Visionary Solutions· 1 model
| Model | Parameters | Setup instructions |
|---|
| PacketAV 4/5 Encoder & Decoder | PasswordreqUsernamereq | This device is monitored over its REST API. Enable API access on the device and provide the administrator username and password; without them, only heartbeat data is available. |