Crestron — Device Setup Parameters
These Crestron models need parameters entered in Xyte after they're claimed. Families that need the same parameters are grouped together below.
Username, Password
Applies to:
- 4 Series
- AirMedia Series
- CEN-ODT-C-POE
- Crestron Flex Conferencing Kits
- Crestron Flex Phones
- Crestron Flex Soundbars
- Crestron Mercury
- DM Matrix Switchers
- DM-NAX Series
- DM-NVX-DIR Series
- DM-NVX Series
- HD-MD 4KZ AV Switchers (REST)
- IV-SAM Series
- TSS/TSW 4-Series Touch Panels
- TS/TSW 60 Series Touch Panels
- UC Engine
Parameters
- Username (required)
- Password (required)
Before you start: TSS/TSW 4-Series and TS/TSW 60 Series touch panels
Xyte signs in to the panel's web page with the username and password you enter, so sign-in must be turned on at the panel:
- On the panel, turn on Authentication.
- Use the administrator account the panel asks you to create, or add a user with the Administrator access level.
- Enter that user's username and password in Xyte.
If Authentication is turned off on the panel, Xyte shows only whether the panel is online or offline. If the panel rejects the username or password, an Edge running a current version also opens a Could not authenticate - heartbeat monitoring only incident.
The Add credentials dialog for these models shows exactly these fields:
Where to enter them
Both routes show the fields above (in the Add credentials dialog from the Devices table, or Edit device credentials from the device page), together with the model's setup instructions when it has any.
From the Devices table — select one or more devices that need these same parameters (they show Missing Credentials), then click Add Credentials in the action bar. The button is enabled only when every selected device has identical requirements (usually the same model):
From the device page — open the device (it shows the isn't reporting data yet banner), then Manage → Edit device credentials:
Once saved, the Missing Credentials flag clears and the device starts reporting — your confirmation it worked.